Ultrasonic Flow

FS-950Clamp-on Ultrasonic Flow Meter

The FS-950 is a non-contact clamp-on ultrasonic flow meter offered in integrated and split configurations. Magnetic sensor alignment, local temperature indication and configurable outputs support fast installation without cutting the pipe or contacting the liquid.

FS-950 Clamp-on Ultrasonic Flow Meter

Technical overview

Published configuration data

Values below describe catalog or typical configurations. The confirmed quotation and model code define the supplied specification.

Accuracy
±2.0% at 0.3-5.0 m/s
Velocity
0.1-5.0 m/s
Response
50 ms
Pipe OD
9.53-116 mm
Viscosity
Below 300 cSt
Protection
IP65

Key characteristics

Why engineers consider FS-950

  • Integrated and split versions
  • Magnetic clamp-on alignment
  • Non-contact liquid measurement
  • 4-20 mA and RS485 Modbus RTU

Typical applications

Where it fits

  • 01Process water
  • 02Chemical reagent lines
  • 03High-purity liquids
  • 04Retrofit flow monitoring

Selection checklist

Confirm these conditions before ordering.

Sending this information helps CurioSens verify the measurement principle, materials, range and interface.

  1. 01Process medium and composition
  2. 02Minimum, normal and maximum flow
  3. 03Operating pressure and temperature
  4. 04Pipe or tube size and process connection
  5. 05Required accuracy and response time
  6. 06Output, power supply and communication interface

Engineer-reviewed FAQ

Questions about FS-950

Application answers reviewed for compatibility, selection, installation and maintenance.

What is the key functional difference between the FS-930 and FS-950 clamp-on flow meters?+

While both the FS-930 and FS-950 share magnetic clamp-on mounting, non-contact measurement, and 2-3 minute setup, the FS-950 adds dedicated temperature sensing capabilities. The FS-950 split model includes an auxiliary temperature sensing wire to display real-time fluid temperature on its 2.4-inch OLED screen alongside flow velocity and totalized volume. Furthermore, the FS-950 split-type offers extended process temperature options up to 120°C, compared to 70°C max on the FS-930 split model. Standard integrated models for both series operate from -10°C to 50°C. Temperature sensor accuracy and thermal coupling grease requirements must be confirmed for the selected configuration. Provide your medium, flow range, pressure, temperature, viscosity, tube size, process connection, and required output to choose the right model.

comparison
When should a split-type clamp-on ultrasonic flow meter be chosen over an integrated model?+

Choosing between integrated and split-type clamp-on flow meters depends on display accessibility and thermal exposure. Integrated models combine the ultrasonic transducers and transmitter display into a single clamped housing, ideal for open, room-temperature piping (-10°C to 50°C). Split-type models like the FS-930 Split or FS-950 Split separate the magnetic transducer clamps from the display controller using a 2.0-meter interconnecting cable (extendable to 20m). This allows the display unit to be wall-mounted in convenient operating locations while transducers operate on process lines running up to 70°C (standard split) or 120°C (high-temp split). Cable routing and anti-corrosion shell options must be confirmed for the selected configuration. Send your medium, flow range, pressure, temperature, viscosity, tube size, process connection, and required output for guidance.

selection
What liquid viscosity limits apply to CurioSens transit-time ultrasonic flow meters?+

Transit-time ultrasonic measurement relies on high-frequency sound waves propagating across moving liquid streams. All standard CurioSens transit-time flow meters—including the FS-910 inline micro-flow meter, FS-920 industrial union meter, FS-930/FS-950 clamp-on series, and FS-9X tubing sensor—are specified for applicable liquid viscosities below 300 cSt (mm2/s). Liquids with higher viscosities, such as heavy oils or concentrated polymers, absorb sound energy and alter laminar velocity profiles, potentially reducing signal-to-noise ratios. For viscous liquids above 300 cSt, positive displacement gear meters like the FP-210 should be evaluated instead. Signal penetration in non-Newtonian liquids must be confirmed for the selected configuration. Share your medium, flow range, pressure, temperature, viscosity, tube size, process connection, and required output with our application engineers.

compatibility
Do clamp-on ultrasonic flow meters cause pressure drop or risk process fluid contamination?+

Clamp-on ultrasonic flow meters represent a non-invasive flow measurement solution. Because transducers clamp directly onto the outer wall of plastic or metal piping (such as FS-930, FS-950, or FS-9X), no internal components restrict fluid motion. This eliminates pressure loss across the meter, reducing pump energy requirements. Furthermore, because no wetted seals or internal sensors contact the liquid, process fluids remain completely free from cross-contamination, leaks, or bio-film accumulation. This non-contact design allows installation and servicing without interrupting active production. Acoustic signal coupling through multi-layer or insulated pipes must be confirmed for the selected configuration. Send your medium, flow range, pressure, temperature, viscosity, tube size, process connection, and required output for evaluation.

selection

Related instruments

Compare the same family.

View family →

Application support

Send us your operating conditions.

Medium, range, pressure, temperature and connection are enough to start a technical selection.