Process Sensors
AS3030-CSterilizable pH Electrode
The AS3030-C is a sterilizable pH electrode for fermentation and related hygienic processes. Its high-temperature gel and ceramic reference system are designed for repeat autoclave exposure and reduced post-sterilization drift.

Technical overview
Published configuration data
Values below describe catalog or typical configurations. The confirmed quotation and model code define the supplied specification.
- Range
- 0-12 pH
- Temperature
- 0-130°C
- Pressure
- 0-5 bar
- Process thread
- PG13.5
- Temperature sensor
- PT1000 or NTC10K with VP
Key characteristics
Why engineers consider AS3030-C
- Autoclave-compatible design
- High-temperature gel
- Ceramic junction
- Custom lengths available
Typical applications
Where it fits
- 01Fermentation
- 02Bioreactors
- 03Hygienic vessels
- 04Research-scale bioprocess
Selection checklist
Confirm these conditions before ordering.
Sending this information helps CurioSens verify the measurement principle, materials, range and interface.
- 01Process medium and composition
- 02Minimum, normal and maximum measuring range
- 03Operating and sterilization temperature
- 04Operating pressure and pressure peaks
- 05Pipe or tube size and process connection
- 06Required output, power supply and control interface
Engineer-reviewed FAQ
Questions about AS3030-C
Application answers reviewed for compatibility, selection, installation and maintenance.
How does the AS3030-C pH electrode minimize calibration drift after autoclave sterilization?+
Autoclaving and steam sterilization subject pH glass membranes and reference junctions to rapid thermal expansion, often causing electrolyte dilution and zero-point drift. The AS3030-C pH electrode incorporates a 200 Mohm sensitive membrane paired with a high-temperature resistant gel formulation and ceramic core reference element. This design maintains reference electrolyte stability, resisting toxic substances and minimizing pH offset after autoclave cycles at temperatures up to 130°C and pressures to 5 bar. Available insertion lengths include 120mm, 150mm, 225mm, 325mm, and 425mm with PG13.5 threads. Because buffer calibration intervals depend on cycle frequency, post-sterilization offset limits must be confirmed for the selected configuration. Send your medium, flow range, pressure, temperature, viscosity, tube size, process connection, and required output for review.
maintenanceHow do I choose between VP, S8, and AK9 cable connectors for my pH electrode installation?+
Selecting the correct electrode connector depends on sensor wiring and environmental sealing needs. The VP (VarioPin) multi-pole connector system (VP6/VP8) carries both high-impedance glass pH signals and integrated PT1000/PT100 temperature sensor lines in one shielded cable, providing IP68 moisture protection ideal for moist or steam-sterilized bioprocess vessels. Standard coaxial connectors like S8 (paired with AS9 cables) or K8S/K9 (paired with AK9 cables) connect single-variable pH signals, requiring separate temperature wiring if needed. Cable options include standard lengths from 1m to 30m. High-humidity environments mandate sealed VP connections. Exact pinouts must be confirmed for the selected configuration. Share your medium, flow range, pressure, temperature, viscosity, tube size, process connection, and required output.
compatibilityRelated instruments